COMPARISON BETWEEN INFUSION SETS AND THE DRIP RATE FORMULA: CONTRIBUTIONS TO ACCURACY IN MEDICATION ADMINISTRATION
Abstract
Accuracy in the administration of intravenous solutions is essential to ensure patient safety and therapeutic effectiveness. In nursing practice, intravenous drip rate calculations are traditionally performed using the proportion of 20 drops per 1 mL. However, differences among infusion sets may alter the volume effectively administered to the patient. This study aimed to identify the number of drops per milliliter among different infusion sets and compare the values obtained with the traditional standard used in intravenous drip rate calculations. This was a semi-experimental study conducted with seven brands of infusion sets used in the city of Rio de Janeiro, Brazil, in which the number of drops required to obtain 1 mL of 0.9% saline solution was analyzed. The results demonstrated significant variations among manufacturers and among infusion sets from the same manufacturer, revealing discrepancies between the values stated on the packaging and the volumes obtained in the experiments. These differences may result in the administration of volumes either greater or smaller than prescribed, compromising therapeutic accuracy and increasing risks associated with intravenous therapy. It is concluded that the standardization of infusion sets and the improvement of quality control processes for these devices are essential to ensure greater accuracy and safety in the intravenous administration of solutions and medications.
Author Biographies
Undergraduate Nursing Student at Veiga de Almeida University (UVA).
Bachelor’s degree in Nursing and Obstetrics from the Fluminense Federal University (1988) and Master’s degree in Cellular and Molecular Biology from the Oswaldo Cruz Foundation (2001). Associate Professor at Fluminense Federal University and Associate Professor at Grande Rio University.
Physician, graduated from Grande Rio University – Prof. José de Souza Herdy (UNIGRANRIO). Bachelor’s degree and Teaching Degree in Nursing from Fluminense Federal University (UFF). Specialist in Occupational Nursing from the State University of Rio de Janeiro (UERJ) and in Infectious Diseases from the Evandro Chagas National Institute of Infectious Diseases (IPEC/FIOCRUZ). Master’s degree in Nursing from UERJ.
Master’s degree in Nursing from the Anna Nery School of Nursing, Federal University of Rio de Janeiro (UFRJ). Bachelor’s degree in Nursing from Fluminense Federal University. Specialist in Public Health Emergency Management and MBA from Fundação Getulio Vargas (FGV-RJ). Assistant Professor at Veiga de Almeida University (UVA) and Nursing Officer of the Rio de Janeiro State Fire Department (CBMERJ), with experience in emergency care, pre-hospital care, disaster response, and health education.
References
AGÊNCIA NACIONAL DE VIGILÂNCIA SANITÁRIA (ANVISA). Boletim de farmacovigilância aborda erros de medicação. Brasília: Anvisa, 2020. Disponível em: https://www.gov.br/anvisa/pt-br/assuntos/noticias-anvisa/2020/boletim-de-farmacovigilancia-aborda-erros-de-medicacao Acesso em: 8 out. 2025.
ASPERHEIM, M. K. Farmacologia para enfermagem. Rio de Janeiro: Guanabara Koogan, 2004.
ATANDA, O.; WEST, J.; STABLES, T.; JOHNSON, C.; MERRIFIELD, R.; KINROSS, J. Flow rate accuracy of infusion devices within healthcare settings: a systematic review. Therapeutic Advances in Drug Safety, v. 14, p. 1-11, 2023. DOI: https://doi.org/10.1177/20420986231188602 DOI: https://doi.org/10.1177/20420986231188602
BRASIL. Ministério da Saúde. Protocolo de segurança na prescrição, uso e administração de medicamentos. Brasília: Ministério da Saúde, 2013. Disponível em: https://www.gov.br/anvisa/pt-
br/centraisdeconteudo/publicacoes/servicosdesaude/publicacoes/protocolo-de-seguranca-na-prescricao-uso-e-administracao-de-medicamentos. Acesso em: 7 out. 2025.
BRUNNER, L. S.; SUDDARTH, D. S. Tratado de enfermagem médico-cirúrgica. Rio de Janeiro: Guanabara Koogan, 2014.
CHOI, J.; KIM, S.; PARK, H. Enhanced accuracy in gravity-based intravenous infusion using pulse oximeter drop counting and measured single-drop weights. Sensors (Basel), v. 24, n. 7, p. 3058, 2024. DOI: https://doi.org/10.3390/s24073058 Disponível em: https://pubmed.ncbi.nlm.nih.gov/40792368/ Acesso em: 19 out. 2025.
FIGUEIREDO, N. M. A. Administração de medicamentos: revisando uma prática de enfermagem. São Caetano do Sul: Difusão Paulista de Enfermagem, 2003.
FIGUEIREDO, N. M. A.; VIANA, D. L. Tratado prático de enfermagem. São Caetano do Sul: Yendis, 2006.
GORSKI, L. A. Phillips's manual of I.V. therapeutics: evidence-based practice for infusion therapy. 7. ed. Philadelphia: F.A. Davis Company, 2018.
HUTTON, B. et al. In vivo accuracy of gravity-flow i.v. infusion systems. American Journal of Hospital Pharmacy, v. 42, n. 9, p. 2204–2208, 1985. Disponível em: https://pubmed.ncbi.nlm.nih.gov/3976679/ Acesso em: 19 out. 2025.
MARTINS, M. J. Q. A.; PECINALLI, N. R.; SIXEL, P. J. Cálculos de gotejamento: validade das fórmulas e comparação entre equipos. Revista Enfermagem UERJ, Rio de Janeiro, v. 11, n. 2, p. 133-138, 2003.
MERRICK, I. M.; MERRICK, T. E. Comparison of drop sizes of intravenous administration sets. American Journal of Hospital Pharmacy, v. 37, n. 10, p. 1346-1350, 1980. DOI: https://doi.org/10.1093/ajhp/37.10.1346 DOI: https://doi.org/10.1093/ajhp/37.10.1346
PAIVA, J. V. B. Administração segura de medicamentos via endovenosa. Revista ITPAC Porto, 2023. Disponível em: https://itpacporto.emnuvens.com.br/revista/article/download/142/115/1066 Acesso em: 7 out. 2025.
SANTOS, J. R. et al. Cálculo de medicamentos: fundamentos e aplicações na prática de enfermagem. Revista Brasileira de Enfermagem, v. 73, n. 5, p. 1–7, 2020. Disponível em: https://www.scielo.br/j/reben/a/ss6dcRRGvy7LYbxCW94zrLH/ Acesso em: 7 out. 2025.
SILVA, L. D.; CAMERINI, F. G. Análise da administração de medicamentos intravenosos em hospital da rede sentinela. Texto & Contexto - Enfermagem, Florianópolis, v. 21, n. 3, p. 633-641, jul./set. 2012. DOI: https://doi.org/10.1590/S0104-07072012000300019