OBTAINING THE TRANSFER FUNCTIONS OF THERMAL SYSTEMS USED FOR TEMPERATURE CONTROL
Abstract
Designing controllers for thermal processes requires understanding the system's dynamics, especially given the thermal inertia and heat losses to the environment. This work aims to obtain and experimentally validate the transfer functions of a thermal water heating plant, using the generated mathematical models to implement and compare different closed-loop temperature control strategies. For this purpose, a physical prototype was built, consisting of a 1000 W relay-driven electric immersion heater, a thermocouple sensor, and an Arduino Uno board operating with PWM modulation. System identification was performed through open-loop step response tests and curve fitting in the MATLAB software, treating both the transducer and the thermal process as first-order systems. The tests resulted in the transfer functions H(s) = 0.15 / (s + 0.15) for the sensor (time constant of 6.67 s) and G(s) = 0.0017 / (s + 0.00095) for the thermal plant (time constant of approximately 1,053 s), proving that the water heating dynamics are about 158 times slower than the measurement element's response. In the practical closed-loop validation under an 80°C setpoint, the On-Off control showed continuous oscillations between 79°C and 83°C due to residual inertia and the actuator's extreme switching. The Proportional controller (Kp = 4) eliminated the overshoot but stabilized at 74°C, maintaining a steady-state error of -6°C. Finally, the addition of the integral action in the Proportional-Integral controller (Kp = 4 and Ti = 600 s) reduced the steady-state deviation to +2°C, demonstrating that prior modeling replaces empirical adjustments with stable control.
Author Biographies
Computer Engineering, Universidade de Araraquara (UNIARA).
Bachelor in Mechatronics Engineering from UFU. Master's student at USP.
References
BATISTA, Lorena Cristina Faria; FERNANDES, Gustavo Queiroz; MAIA, Antônio Augusto Torres. Estudo comparativo de técnicas de sintonia de controladores PID para sistemas de primeira ordem com atraso. In: ABCM Symposium Series in Mechatronics, v. 6, p. 1144-1153, 2014.
BAYER, Fernando Mariano; ARAÚJO, Olinto César Bassi de. Controle Automático de Processos. 3. ed. Santa Maria: Universidade Federal de Santa Maria, Colégio Técnico Industrial de Santa Maria; Rede e-Tec Brasil, 2011. 92 p.
FREITAS, Felipe Câmara de. Regras de sintonia do preditor de Smith filtrado simplificado para sistemas de primeira ordem com atraso. 2025. 53 f. Dissertação (Mestrado em Engenharia Elétrica) - Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2025.
INCROPERA, Frank P. et al. Origens físicas e equações de taxa. In: INCROPERA, Frank P. et al. Fundamentos de transferência de calor e de massa. 6. ed. Rio de Janeiro: LTC, 2008. p. 2-21.
LARA, Pedro Augusto de Oliveira; HERRERA, Cristhiano da Costa. Implementação Didática de Controle de Temperatura: Comparação entre PID Digital e On-Off. Revista Brasileira de Iniciação Científica (RBIC), Itapetininga, v. 13, art. e026011, p. 1-19, 2026.
NISE, Norman S. Engenharia de Sistemas de Controle. 6. ed. Rio de Janeiro: LTC, 2012.
OGATA, Katsuhiko. Engenharia de Controle Moderno. 5. ed. São Paulo: Pearson, 2010.
SMITH, Carlos A.; CORRIPIO, Armando B. Princípios e Prática do Controle Automático. 2. ed. Rio de Janeiro: LTC, 2006.
